Melaklean Cleaner Air Products Total Microbe test kit
28 September, 2010 | Supplied by: Melaklean Cleaner Air Products
The Total Microbe easy-to-use test kit gives an answer in 24 hours or under, if the contamination is substantial. It can be used on process water, drinking water, wastewater or recycled water.
Gonotec Osmomat 030 Cryoscopic Osmometer
20 September, 2010 | Supplied by: Gallay Medical & Scientific Pty Ltd
An updated version of the Gonotec Osmomat 030 Cryoscopic Osmometer is available with option 3P that allows calibration with water and two further adjustable calibration points, creating a more reliable and accurate standard curve.
TecQuipment modular Structures teaching system
20 September, 2010 | Supplied by: Duff & Macintosh
The TecQuipment modular Structures teaching system range, available from Edutechnics/Duff and Macintosh, can be used for engineering teaching in tertiary laboratories.
Label-free ligand fishing
06 September, 2010 by Elodie Ly-Morin, Wilfrid Boireau, Patrick Ducouroy, Sophie Bellon, Chiraz Frydman
Surface plasmon resonance (SPR) is an emerging technique in the bio and life-science markets. It offers a new generation of label-free biomolecular analyses, providing information on kinetic processes (association and dissociation), binding affinity, analyte concentration and real-time molecule detection. It has become a powerful tool for the analysis of biomolecular events involved in drug development, cancer research, antibody screening and more.
Microfluidic HIV test
06 September, 2010
A microfluidic device uses antibodies to ‘capture’ white blood cells called T cells affected by HIV.
BOC Gases Baseline cylinder regulators
02 September, 2010 | Supplied by: BOC Limited
Baseline cylinder regulators have been specifically designed to maintain the integrity of high-purity, specialty gases.
Belimed Vapofix steriliser
23 August, 2010 | Supplied by: Gallay Medical & Scientific Pty Ltd
The Belimed Vapofix steriliser features a square chamber, small footprint, touch-screen user interface and long-life door seals, and is suitable for medical, dental and laboratory applications.
Viaflo Voyager adjustable spacing handheld pipette
09 August, 2010 | Supplied by: BioTools Pty Ltd
Viaflo’s Voyager handheld pipette features electronically adjustable channel spacing to simplify transferring liquid between different labware formats.
Torrey Pines Scientific 5- and 9-position hotplates and stirrers
06 August, 2010 | Supplied by: Edwards Group Pty Ltd
Torrey Pines Scientific has released a line of multiposition analog stirring hotplates and stirrers featuring 5 or 9 stirrers.
Palintest industrial water test kits
06 August, 2010 | Supplied by: Palintest Ltd
Palintest has released a range of all-in-one industrial water test kits which are suitable for a wide range of field testing requirements. The range is designed to bring together all the necessary tools for accurate, quick and easy water testing for a variety of industrial applications.
Arctic refrigerated circulators
06 August, 2010 | Supplied by: Rheology Solutions Pty Ltd
Arctic refrigerated circulators feature a stainless steel reservoir and are offered in a range of sizes and depths. With capacities from 5 to 30 L, units offer recessed handles and a drain port opening at the front. The advanced ventilation design allows two sides of the bath to be blocked (allowing placement in a room corner) and still deliver full refrigeration performance without affecting the equipment. Temperature range of the series is from -25 to +150°C.
Hach No Glass pH system
06 August, 2010 | Supplied by: Accurate Detection Pty Ltd
The Hach H series rugged portable pH meter systems provide a large LCD with LED backlight and measurement of pH (ISFET or glass), mV, temperature, conductivity, total dissolved solids (TDS), salinity and oxidation reduction potential (ORP).
Thomas Cain DEENA automated acid digestion system
06 August, 2010 | Supplied by: Accurate Detection Pty Ltd
The Thomas Cain DEENA automated acid digestion system fully automates the sample preparation for EPA and other laboratory methods that use hot water baths or heated blocks. Typically in metal and mercury analysis, manual sample preparation often consists of many steps that are both labour intensive and time consuming and expose the operator to dangerous chemicals.
Kartell pipette filler (Art. 200)
06 August, 2010 | Supplied by: Sieper & Co Pty Ltd
Kartell’s pipette filler (Art. 200) is a moulded bulb made of synthetic rubber and has an approximate capacity of 60 mL. Three glass ball valves control the evacuation of air, liquid uptake and liquid dispensing. The valves are controlled by finger pressure. Users expel air from the bulb by squeezing the ‘A’ valve and the bulb at the same time. Liquid is drawn into the pipette by squeezing the ‘S’ valve and dispensed by squeezing the ‘E’ valve.
Scientifica PatchStar electrophysiology micromanipulator
06 August, 2010 | Supplied by: SciTech Pty Ltd
The Scientifica PatchStar electrophysiology micromanipulator is suitable for patch clamping, sharp electrode recording, microinjection, stretch testing and other procedures requiring delicate and long-term positioning.