Products

Cell Density Meter

19 August, 2002 | Radiometer Pacific Pty Ltd

The WPA Cell Density Meter is a compact instrument that provides instant cell density readings at the touch of a button. The Biowave CO8000 is a low cost easy to use portable cell density meter with wavelength 600 nm, range -0.3 to 1.99 A, RS-232 output and a custom LCD. The Biowave CO8000 cell density meter is neat and compact, taking up less bench space than a spectrophotometer. Readily portable, it can be used anywhere needed, eliminating the safety hazard of carrying bacterial samples to and from a fixed instrument. It is no problem to use it within a laminar flow cabinet so that work with micro-organisms can be completed without leaving the sterile bench.

Laboratory Tubing Connectors

19 August, 2002 | Omnifit Ltd

Omnifit's inert colour-coded connectors provide a simple, versatile system for connecting different types of laboratory tubing instantly, including PTFE, glass, silicone and stainless steel. Applications include sampling, stream splitting, mixing and fluid line interconnection.

Gene Arrays

15 July, 2002 | Merck

Panorama gene arrays provide a semi-quantitative platform for analysis of the expression of hundreds of genes in a single experiment.

AA for Semiconductor Applications

15 July, 2002 | Thermo Fisher Scientific

Thermo Elemental has responded to the corrosive sample issues of the semiconductor industry with a specially configured AA system. High purity solvents, acids and cleaning fluids must be strictly controlled and monitored at critical points throughout the production process and they are routinely checked at the sub-ppb level for the main impurity elements, including Na, Ca, Cu, Fe and Ni.

Ducted Fume Extraction

15 July, 2002 | Laboratory Systems Group

The Smoothflow 2000 series of fume cupboards is manufactured with double sidewall construction to provide sidewall mounted service outlets. This aids containment and eliminates flow reversal due to eddy currents caused by protruding mullions.

InGaAs Array

15 July, 2002 | Lastek Pty Ltd

The Optical Spectroscopy Division of Jobin Yvon has released a new generation of the IGA3000 Near Infrared Array Series.

Ductless Fume Hoods

15 July, 2002 | AirClean Systems Australia

AirClean Systems portable ductless fume hoods remove toxins by filtration while protecting operators and the environment. The units are suitable for laboratories where small volume chemicals are being used and where a ducted fume cupboard is not viable.

High Temperature Microscopy Stage

17 June, 2002 | Warsash Scientific Pty Ltd

The Linkam TS1500 High Temperature Stage is 104 x 95 x 29 mm. It produces a temperature range from ambient to 1500°C and contains a type S PI-10% Rh/P1 thermocouple. A 7 mm sapphire sample disc makes contact with the thermocouple to ensure an accurate temperature measurement from the sample.

Non-Contact Level Measurement

17 June, 2002 | Endress+Hauser Australia Pty Ltd

The Prosonic M compact, ultrasonic level transmitter uses non-contact, non-intrusive level measurement to measure up to 15 m in liquids and 7 m in solids.

Disposable Robotic Reservoirs

17 June, 2002 | Interpath Services Pty Ltd

Nalgene has a range of disposable robotic reservoirs for use in automated processes. A standard microplate format with a 300 mL working volume, the Nalgene Disposable Reservoir is available in two styles.

Air Cleaner

17 June, 2002 | Bio-Oxygen Aust Pty Ltd

Bio-Oxygen is a natural air cleaning process in which no disinfectants, perfumes, catalysts or chemicals are used and which allows the air quality to be monitored 24 hours a day, 7 days a week - in real-time.

Helium Detector

17 June, 2002 | Grace Discovery Sciences

Alltech's helium leak detector is a portable gas leak detector that pinpoints leaks in applications such as gas capillary systems in difficult to reach and confined locations. The detector uses a highly sensitive thermal actuated cell and signal amplification to detect leaks. When a leak is detected, a signal is displayed on the unit's LED display as well as sounding an audible alarm.

OxyBaby oxygen analyser

16 June, 2002 | Niche Gas Products

The OxyBaby handheld MAP oxygen analyser can be used to check residual oxygen levels at regular intervals. OxyBaby is handy, doesn't require power leads and is simple to use. It is portable and suitable for making quality checks of packed foods such as meats, sausages, fish, dairy products, bakery products, pasta, pizza and salads. Oxygen levels can be determined at any time by simply picking a pack off the line and inserting the needle. OxyBaby is designed so that it can be held in one hand with the packaged food product in the other.

Genetic Analysis System

20 May, 2002 | Beckman Coulter Australia

The CEQ 8000 Genetic Analysis System automates and integrates the majority of genetic analysis functions into one flexible, easy to use system. With one gel, one array and one software platform, users can perform DNA sequencing, heterozygote detection, confirmatory sequencing, mutation analysis, allele identification, SNP (single nucleotide polymorphism) scoring, microsatellite instability and AFLP (amplified fragment length polymorphism) fingerprinting.

Hygiene Monitoring System

20 May, 2002 | BEST Lab Instrumentation Pty Ltd

The new Lumitester PD10, Portable Luminometer, and Lumipac W, hygiene test swabs, offer a quick and simple hygiene test for anyone in the food production, delivery, restaurant, catering or medical industry where confirmation of the status of bacterial contamination is needed.

  • All content Copyright © 2026 Westwick-Farrow Pty Ltd