Analytical instrumentation

Jasco V-630Bio UV-Vis Spectrophotometer

06 May, 2013 | Supplied by: ATA Scientific Pty Ltd

The V-630Bio UV-Vis spectrophotometer from Jasco features a rugged and compact design, good optical performance, high-speed scanning (190 to 1100 nm) and versatility. Only 0.6 µL of sample volume are required using the one drop accessory.


High-speed discovery helps measure greenhouse gases from space

02 May, 2013

Scientists have discovered how to measure greenhouse gases 200,000 times faster as the result of research by an award-winning PhD student from The University of Western Australia (UWA) and a US team.


Agilent 7890B gas chromatograph and the 5977A Series mass selective detector

01 May, 2013 | Supplied by: Agilent Technologies Australia Pty Ltd

Agilent Technologies has introduced the Agilent 7890B gas chromatograph and the 5977A Series mass selective detector.


Shimadzu LCMS-8040 for analysis of pesticides in food samples

30 April, 2013 | Supplied by: Shimadzu Scientific Instruments (Oceania) Pty Ltd

Pesticides and their metabolites are of great concern to society as they are harmful to human health, pollute natural resources and disturb the equilibrium of the ecosystem. Consequently, stricter food safety regulations are being enforced around the world. Triple quadrupole LCMS systems can deliver high sensitivity and identification of the compounds of concern.


Robust oxygen analyser helps composting process for organic fertiliser

29 April, 2013 | Supplied by: AMS Instrumentation & Calibration Pty Ltd

An organic fertiliser manufacturer has selected Michell Instruments’ XZR500 to monitor oxygen levels in its composting process. The innovative process dramatically reduces the time taken to break down animal dung into a useable form and the XZR500 forms part of the control system.


POCD Scientific Eppendorf spectrophotometer range

29 April, 2013 | Supplied by: Point of Care Diagnostics

Eppendorf offers a full range of spectrophotometers: from the entry-level D30, specifically for DNA, RNA and protein quantitation, to the full-spectrum tuneable, kinetic and scanning systems - the Basic and Kinetic models.


BioTek Cytation3 Cell Imaging Multi-Mode reader

26 April, 2013 | Supplied by: http://www.mscience.com.au/view/biotek/cytation3

The Cytation3 Cell Imaging Multi-Mode reader from BioTek combines automated digital microscopy with conventional microplate reading in one instrument. The patent-pending design of the product provides rich phenotypic cellular information with well-based quantitative data.


Eppendorf BioPhotometer D30

24 April, 2013 | Supplied by: Eppendorf South Pacific Pty Ltd

Eppendorf has extended its range of detection instruments for life sciences applications. With the Eppendorf BioPhotometer D30, measurement data is recorded for fixed wavelengths, making the device suitable for routine applications.


Spectral patterns of benzene dimer finally deciphered

22 April, 2013

A spectrum of the benzene dimer was first recorded in 1993, with the aim to find out more about its structure and dynamics. The experiments produced characteristic patterns with four peaks, which no one could decipher for 20 years. Now, using a new theoretical model and the experimental data gathered in Berlin, the spectral patterns have been successfully deciphered and the dynamics that cause them explained.


Ultrafast high-resolution imaging in real time

22 April, 2013

Ultrafast high-resolution imaging in real time could be a reality with a new research discovery led by the University of Melbourne.


Restek electronic leak detector for gas chromatographs

19 April, 2013 | Supplied by: Leco Australia Pty Ltd

Restek’s redesigned leak detector is an important tool for the troubleshooting and routine maintenance of gas chromatographs. By checking for leaks often, the GC column and instrument will be protected from damage and loss of sensitivity.


Shimadzu Nexera X2 UHPLC system

15 April, 2013 | Supplied by: Shimadzu Scientific Instruments (Oceania) Pty Ltd

The Nexera X2 UHPLC system from Shimadzu showcases innovative technologies for improving UHPLC method development and operation.


Thermo Scientific SureStop 9 mm Vial

12 April, 2013 | Supplied by: Thermo Fisher Scientific

The Thermo Scientific SureStop 9 mm Vial is designed as part of the Advanced Vial Closure System (AVCS). It removes any subjectivity around achieving the optimal compression of the septum when sealing a chromatography vial.


What happens when a chemical bond is broken?

09 April, 2013

That question was recently answered with the help of a so-called free electron X-ray laser, which makes it possible to follow in real time how bindings in a molecule are changed and broken. The study, published in Science, found, among other things, evidence of a much-discussed intermediate state before molecules bind to or leave a metal surface. The possibility of monitoring at the molecular level how the electron structure changes in a chemical reaction creates entirely new opportunities for investigating and understanding key chemical processes in detail.


Mechanism of Click chemistry reveals its secrets

08 April, 2013

Click chemistry is not a specific reaction but rather chemistry tailored to generate substances quickly and reliably by joining small units together. It is meant to mimic nature which also generates substances by joining small modular units (eg, amino acids into proteins). But precisely how it works had been unclear since its invention at The Scripps Research Institute (TSRI) more than a decade ago.


  • All content Copyright © 2024 Westwick-Farrow Pty Ltd