Products

Pipetting robot

18 August, 2003 | Millennium Science Pty Ltd

Theonyx is an automation platform developed by MWG Biotech in partnership with Sias AG. Theonyx is characterised by flexibility as the system's modular set-up allows the combination of a multitude of functions on just one robot. Liquid handling dynamics are driven by a micro annular gear pump mechanism within the robot arm itself. For the user this means a dynamic range of less than 1 µL up to more than 3 mL, within a single pipetting action, and without compromises in accuracy or precision.

Microscopy platform

18 August, 2003 | Leica Microsystems Pty Ltd

Leica Microsystems has released a series of digital microscopes that simplify microscopy. The series includes the Leica DM4000 B and DM5000 B for routine and research biological applications, diagnostics, cancer research, cell biology and biotechnology.

Quantitative innoculating loops

18 August, 2003 | Interpath Services Pty Ltd

Interpath Services has a range of accurately calibrated nickel-chrome (NiChrome) wire loops for performing quantitative specimen cultures.

Ion trap mass spectrometer

18 August, 2003 | Keysight Technologies Australia Pty Ltd

Agilent Technologies has introduced an ion trap mass spectrometer that is claimed to be approximately 10 times more sensitive than its predecessor. The increased sensitivity, resolution and scan speed of the Agilent 1100 Series LC/MSD Trap XCT promise improved performance for many applications such as the identification and characterisation of biologically significant, low-abundance proteins for disease research.

Portable digital vibrometer

14 July, 2003 | Warsash Scientific Pty Ltd

Polytec's portable multi-purpose non-contact vibration system, the PDV-100 combines optics and digital signal processing to measure surface vibration velocity without contact, utilising Laser Doppler Vibrometry (LDV) technology. The system yields good measurement performance, ease of use and long-term calibration stability in a portable and robust package.

IR thermometer/camera

14 July, 2003 | ECEFast

The Raytek MX6 is a handheld infrared thermometer with integral digital camera. Temperature measurements are made instantly and easily with the full function thermometer in the range of -30 to 900°C or with SZ option from -50 to 500°C. The target is accurately indicated with a bright coaxial circular laser which is accurate at any distance. Standard optics provide 60:1 distance to target ratio, while the CF option allows targets as small as 6 mm at 300 mm. The MX6 can be programmed with up to 100 customised locations by name and with alarms.

Flash point tester

14 July, 2003 | John Morris Scientific Pty Ltd

The Setaflash Series 3 flash point tester has been designed for rapid testing and spot checks for most user applications. Checking flash point is important during inspection and analysis of many products. For example, in the classification of potentially hazardous substances where storage, transport and disposal charges are based on flammability and where incorrect classification can lead to significant added costs.

Laboratory catalogue

14 July, 2003 | Hanna Instruments Pty Ltd

Hanna Instruments 2003 General Catalogue (25th Edition) is available for distribution.

Tubing assembly

14 July, 2003 | Omnifit Ltd

Omnifit has developed a tubing assembly with leak-tight gripper fittings for fluid transfer in spectrophotometers. Each flow cell consists of a glass tube held in an aluminium housing. The requirement was for a PTFE tubing assembly with fittings that would seal to the glass surface of the flow cell while accommodating variations in the alignment between the cell and its housing. The dimensions of the flow cell tubing were 1.6 mm OD and 1.0 mm ID.

Film seal testing

14 July, 2003 | IDM Instruments

The Hot Tack Tester is an advanced system for monitoring the seal performance of flexible and semi-rigid plastic films and laminates.

Analytical QC LIMS

14 July, 2003 | Thermo Electron Corporation

Thermo LabSystems has announced that Analytical Quality Control (AQC) functionality is now available as part of the latest version of its Nautilus LIMS (Laboratory Information Management System).

LA300 particle size analyser

14 July, 2003 | BEST Lab Instrumentation Pty Ltd

The LA300 is a QC instrument designed for liquid dispersion work in the range 0.1 to 600 µm, and is suitable for pharmaceutical applications. It is compact, easy to use, and able to handle difficult sample types with ease.

Ductless fume cabinets

14 July, 2003 | Gallay Medical & Scientific Pty Ltd

The Captair range of ductless recirculating fume cabinets is suitable when the installation of a fully ducted system is difficult or uneconomical within an existing work environment. Duct route, exhaust location or existing walls can make a ducted system too expensive and complicated.

Automated pipette

14 July, 2003 | VWR International Pty Ltd

The 'HandyStep electronic' from Brand is a microprocessor-controlled, battery-operated pipette with automatic tip size recognition for the encoded Plastibrand PD-Tips. It is also compatible with most standard dispenser tips, including Combitips and Combitips Plus, by manually entering the tip size.

Quadrupole ICP-MS

16 June, 2003 | Varian Australia Pty Ltd

Varian has released a sensitive quadrupole ICP-MS (Inductively Coupled Plasma - Mass Spectrometry) instrument designed to achieve gigahertz sensitivity (1000 million counts per second per ppm of analyte) while delivering improved performance across other criteria. Sensitivity is a key factor in detection limits, and with environmental and other regulations calling for increasingly lower detection limits, ICP-MS is becoming the analysis tool of choice in a number of industries.

  • All content Copyright © 2026 Westwick-Farrow Pty Ltd